XIV Final Thoughts- Drive Failures a Red Herring?

UPDATE [8/6/2010]:  If you're interested in more current XIV information, I recommend reading Tony Pearson's recent posts here and here.  He also provided additional information in the comments to one of my posts here.
--

Over the past few weeks, between the Wave and the blog posts, I've been thinking about XIV quite a bit. It has taken IBM quite a while to attempt to explain the impact and risk of double drive failures on XIV.

IBM definitely has an explanation, one that could have been told quite a bit ago.  In fact, I'd assume that this is the same explanation they've been giving customers who pushed the point; that the risk is less that it seems due to quick rebuilds and the way parity is distributed between interface and data nodes.  I realize that UREs are a very large concern, but to be honest, I bet less than 5% of customers even think about storage at that level.  Perhaps the double drive failure issue is just a red herring that draws attention away from other issues.

One thing that continues to stick out in my mind is the ratio of interface nodes to data nodes.  On the Google Wave, on of the IBM VARs made the following statement:
Remember there is more capacity in the data modules than in the interface modules.  (9 data, 6 interface)  Why they couldn't make this easy and have an equal number of both module types, I'll never know!  :) 
The interface nodes are only 40% of the array.  Even IBM VARs can't explain why this is a 40:60 ratio rather than 50:50.  It increases the probability of double drive faults causing data loss at high capacity and it is a pretty specific design decision.

I wonder if it is related to the Gig-E interconnect and driving out "acceptable" performance from non-interface nodes.  Jesse over at 50 Micron shares similar thoughts.  Thinking this through (and this is all simply a hypothesis)... perhaps the latency and other limitations of the Gig-E interconnect are somewhat offset by having additional spindles (IOPS+throughput) on the "remote data nodes."  I'd like to load a XIV frame to 50% utilization, run a 100% read workload at it, and see if the interface nodes are hit much harder than the data nodes (in effect, performing like a RAID 0, not a RAID 1).  If that were true, for optimal performance you'd never want to load a frame past the point where new volumes would be allocated solely from data nodes.

I am not claiming this is true (no way for me to test it), but if XIV changes the interconnect to a different type (Infiniband, for example), I will find it interesting if "suddenly" there is a 50:50 ratio of interface to data nodes.

Monday, March 22, 2010

XIV Recap

UPDATE [8/6/2010]:  If you're interested in more current XIV information, I recommend reading Tony Pearson's recent posts here and here.  He also provided additional information in the comments to one of my posts here.
--

A few weeks ago, I created a Google Wave to discuss the architecture surrounding XIV and the related FUD (some of it fact-based) that this architecture attracted.  I intended to post a recap after the wave had died down.

This is not that recap.  The recap was about 80% complete, but more reputable resources have posted much of the same information.  For anyone interested in the actual Wave information, contact me and I'll send a PDF (provided there is some mechanism to decently print the Wave).  There was a podcast Nigel hosted last week that I participated in available on his podcast archives.

New Zealand IBMer the Storage Buddhist wrote this post discussing the disk layout and points of failure in IBM's XIV array... which generated this response by NetApp's Alex McDonald.  Both posts, especially the comments, are interesting and show both sides of the argument around disk reliability for XIV.

This post is meant to bridge a few gaps on both sides, and requires a little disclaimer.  Most of the technical information below came from the Google Wave, primarily from IBM badged employees and VARs.  I have been unable to independently guarantee accuracy- even the IBM RedBook on XIV has diagrams of data layout that contradict these explanations, but with disclaimers that basically say the diagrams are for illustrative purposes and don't actually show how it really works.  So, caveat emptor - make sure you go over the architecture's tradeoffs with your sales team.

Hosts are connected to the XIV through interface nodes.  Interface nodes are 6 of the 15 servers in an XIV system have FC and iSCSI Ethernet interfaces providing host connectivity.  Prior to an unspecified capacity threshold, each incoming write is written to an interface node (most likely the one it came in on) and mirrored to a data node (one of the 9 other servers in an XIV system).

At this point, you can have drive failures in multiple interface nodes without data loss.  In fact, one person claimed that you could lose all of the interface nodes without losing any data (of course, this would halt the array).  The "data-loss" risk in this case is losing one drive in an interface module (40% of the disks) followed by one drive in a data module (60% of the disks) prior to a rebuild being complete (approximated at, worst case, 30-40 minutes).  Or, as it was put in the wave:
"If I lose a drive from any of a pool of 72 drives, and then I lose a second disk from a separate pool of 108 drives before the rebuild completes for the first drive, I'm going to have a pretty huge problem." 
Past a certain unknown threshold, incoming writes start getting mirrored between two data nodes rather than an interface node and a data node.  At that point, double disk failures between different data nodes can also cause a pretty huge problem.

From a 'hot spare' perspective, the XIV has space capacity to cover 15 drive failures.  When you hear XIV resources discuss "sequential failures," they typically mean drive failures that occur after the previous one has rebuilt, but prior to the replacement of the failed drive.  This is an important statistic from the perspective of double drive failures that occur because the failed drive was never detected (have you verified YOUR phone home lately?).

A couple of final thoughts.  First off, the effect of a uncorrectable error during a rebuild was never fully explained.  I have heard in passing that "the lab" can tell you what the affected volume is and that it shouldn't cause the same impact as two failed drives.  Secondly, Hector Servadac mentions the following on the StorageBuddhist's post:
2 disk failures in specific nodes each one, during a 30 min windows, is likely as 2 controller failure
Unless I'm not understanding the impact of a 2 controller failure, there is no data loss with that type of 'unlikely' failure... with the double drive failure, there is significant data loss.  But as a yardstick of "how likely does XIV/IBM feel this outage scenario is," it serves as a decent yardstick.

I tried to make this as unbiased as possible.  I am positive I will be brutally corrected in the comments :-).

Tuesday, March 16, 2010

Breaking Datacenter Boundaries

Chuck Hollis (EMC) has an interesting post up regarding the future of workload optimization and fluid architectures.  First off, he has one of the clearest definitions of cloud architecture and private clouds I've seen recently:
"What makes a cloud a cloud is three things: technology (dynamic pools of virtual resources), operations (low-touch and zero-touch service delivery) and consumption (convenient consumption models, including pay as you go)... What makes a cloud "private" is that IT exerts control over the resources and associated service delivery."
Let's take a look at today's dynamic datacenter, especially in an organization where private cloud is being pursued.

  1. You have a very high virtualization rate.  Due to less friction for resource acquisition, you can assume that more and more systems will become virtualized on the private cloud as time goes on.
  2. You have a variable cost model, allowing for changing costs based off of actual consumption and performance utilization.
  3. You have an automation engine, to drive processes/systems through the private cloud.
  4. Regardless of technology, you're hopefully pursuing loosely coupled systems that do not have low latency requirements and provide rich web interfaces.
From a technology play, you have at least most of these in play:
  1. VMware - VMs are moving among hosts based on dynamic workload decisions - "where" something is running becomes less important.
  2. Intelligent Storage Optimization - placing the right data in the right place without sacrificing performance.
  3. Replication - ensuring production data is recoverable in a remote location.
Virtualization allows IT organizations to break down silos and drive utilization up while controlling costs.  Most large organizations maintain several data centers, and resources are not easily shared between them.  That's the next silo to be knocked down... by leveraging the investment in virtualization and storage technologies, it could be possible in the near future.
  1. You have extremely high visibility into utilization, data traffic, response times, frequency... basically, what drives the physical location of a VM.  The main reason not to move a workload to a different data center typically has to do with latency between users and the application layer, or between the application layer and the data.  By hooking into the hypervisor, you could determine likely candidates that can be moved without massively disrupting the user experience.
  2. The "heavy lifting" of migrating large portions of production data is already taken care of.  You have an asynchronous mirror of the data at the remote site, probably hooked up to an existing VMware Cluster.  The remain "system state" information could be replicated with a brief outage at a predefined window and then promoted to production at the remote site (flipping the replication to maintain recoverability).
Given the end-to-end knowledge from #1, and the data proximity of #2, you can theoretically "warm" migrate a VM from one datacenter to another, keeping response times the same or better, and increase the flexibility of the environments.

So, in the end, it comes down to what percentage of applications are eligible for this type of workload distribution based on network and performance requirements.  By optimizing at that level, you can more evenly spread out your workload requirements geographically.  The notion of distributed cache coherence comes into play for applications that don't behave well in a higher latency location.  Finally, once you have that technology in place, disaster recovery becomes much simpler - instead of vMotioning between hosts, you vMotion to an alternate datacenter.

Sure, none of this is available right now... but looking forward, you can see how an entirely fluid, geographically dispersed IT infrastructure is possible.